RH850/F1Kx, RH850/F1K Series Hardware Design Guide
R01AN3841ED0110 Rev. 1.10 Page 86 of 108
August 8, 2019
5. SENT Interface (RH850/F1Kx Series only)
The SENT module supports the SPC (Short PWM Code) extension of the J2716 specification that introduces a bi-
directional and synchronous communication. The SPC extension can be enabled by software (by RSENTnCC.SPCE
bit).
When the SPC extension is used an external transistor is required in order to pull-down the RX line to initiate a SENT
message transmission. In the RH850/F1Kx series this is realized by controlling an external transistor connected to the
RSENTnSPCO pin. The polarity of the RSENTnSPCO pin can be configured by software (by RSENTnCC.SOPC bit).

Table of Contents