68
Debugging
Echo: O Debugging information that is sent to the software (irrelevant for normal operation)
Info: O Debugging information that is sent to the software (irrelevant for normal operation)
Errors: O Debugging information that is sent to the software (irrelevant for normal operation)
Dry run: O Debugging information that is sent to the software (irrelevant for normal operation)
Configuration
General Baud rate:250000 Setting of the transfer speed from the computer
Stepper Inactive Time setting until the motors are switched o in standby
Max. Inactive Time setting until the display is switched o in standby
Acceleration Print X: 1000 Setting of the printing acceleration of the X-axis
Print Y: 1000 Setting of the printing acceleration of the Y-axis
Print Z: 1000 Setting of the printing acceleration of the Z-axis
Move X:1000 Setting of the travel speed of the X-axis
Move Y:1000 Setting of the travel speed of the Y-axis
Move Z:1000 Setting of the travel speed of the Z-axis
Jerk :10.0 Acceleration of X and Y axis at small steps
Z-Jerk : 20.0 Acceleration of Z-axis in small steps
Feed rate Max X: 500 Max. speed of the X-axis
Max Y: 500 Max. speed of the Y-axis
Max Z: 50 Max. speed of the Z-axis
Home X: 200 Max. speed of the X-axis when moving to the home position
Home Y: 200 Max. speed of the Y-axis when moving to the home position
Home Z: 20 Max. speed of the Z-axis when moving to the home position
Extruder Steps/mm 71.0 Basic setting extruder / ATTENTION: do not adjust
Start FR: 18 Basic setting extruder / ATTENTION: do not adjust
Max FR 25 Basic setting extruder / ATTENTION: do not adjust
Accel:6000 Basic setting extruder / ATTENTION: do not adjust
Stab. Time: 20 Basic setting extruder / ATTENTION: do not adjust
Wait Units: 0 mm Basic setting extruder / ATTENTION: do not adjust
Wait Temp. 150°C Basic setting extruder / ATTENTION: do not adjust
Advance lin: 0 Basic setting extruder / ATTENTION: do not adjust
Advance quad: 0 Basic setting extruder / ATTENTION: do not adjust
Control:PID Basic setting extruder / ATTENTION: do not adjust
DT/PID P: 37.52 Basic setting extruder / ATTENTION: do not adjust
PID I: 10.00 Basic setting extruder / ATTENTION: do not adjust
PID D: 35.18 Basic setting extruder / ATTENTION: do not adjust
Drive Min: 60 Basic setting extruder / ATTENTION: do not adjust
Drive Max: 130 Basic setting extruder / ATTENTION: do not adjust
PID Max: 255 Basic setting extruder / ATTENTION: do not adjust
Z Calib Home All
Move all axes into the home position
Z Position
Move Z-axis into a settable position / display of the limit switch condition
Heat Bed Scan Heating bed calibration

Table of Contents