Page #16 background imageLoading...
Page #16 background image
DeltaSol
®
BS
© RESOL 04272 deltasol_bs.mon.pmd
| 16
For control and service work the operating mode of the
controller can be manually adjusted by selecting the
adjustment value MM, in which the following adjustments
can be made:
4.1.18 Operating mode
HND1 / HND2
Operating mode
OFF : relay off (flashing) +
AUTO : relay in automatic operation
ON : relay on (flashing) +
HAND / HND1 / HND2:
BOperating mode
Adjustment range:
OFF, AUTO, ON
Factory setting: AUTO
4.1.17 Pump speed control
A relative minimum pump speed is specified for pumps
connected at the outputs R1 and R2 via adjustment
channel nMN.
Attention:
When using consumers (e.g. valves) which are not
pump speed controlled, the value must be
adjusted to 100 % in order to deactivate the pump
speed control.
nMN:
Pump speed control
Adjustment range:
30 ... 100
Factory setting: 30
(PG 67.30 and PG 69.30)
4.1.19 Language
The menu language can be adjusted in this channel.
dE : German
En : English
LANG:
Adjustment of language
Adjustment range: dE, En
Factory setting: dE

Other manuals for Resol DeltaSol BS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Resol DeltaSol BS and is the answer not in the manual?

Resol DeltaSol BS Specifications

General IconGeneral
TypeSolar Thermal Controller
Number of Inputs4
Number of Outputs2
Outputs2 relay outputs
Enclosure ProtectionIP20
Temperature Sensor Inputs4 (Pt1000)
MountingWall-mounted
Power Supply220 … 240 V~

Related product manuals