EasyManua.ls Logo

Resol DeltaTherm FK - Page 15

Resol DeltaTherm FK
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
en
15
Installation
CommissioningSettingsTroubleshooting
Accessories
Display
Commissioning menu
9. Maximum store temperature
Î Adjust the desired maximum store
temperature
Tmax store
Maximum store temperature (cursor)
Adjustment range: 30 ... 90 °C
Factory setting: 90 °C
10. Emergency shutdown temper-
ature
Î Adjust the desired emergency
shutdown temperature of the solid
fuel boiler
Temerg SFB/boiler
Emergency shutdown temperature
Adjustment range: 80 ... 105 °C
Factory setting: 95 °C
11. Save
Completing the commissioning
menu
The last menu item of the commission-
ing menu is Save. If you select Save,
all adjustments carried out in the com-
missioning menu will be confi rmed and
saved.
Î In order to confi rm the adjust-
ments made in the commissioning
menu, press button 3
The controller is then ready for opera-
tion with the adjustments made for the
selected system.
The adjustments carried out during
commissioning can be changed after
commissioning anytime in the corre-
sponding adjustment channel.
Additional functions and options can
also be activated or deactivated.

Related product manuals