Installation
CommissioningSettingsTroubleshooting
Accessories
Display
Commissioning menu
9. Maximum store temperature
Î Adjust the desired maximum store
temperature
Tmax store
Maximum store temperature (cursor)
Adjustment range: 30 ... 90 °C
Factory setting: 90 °C
10. Emergency shutdown temper-
ature
Î Adjust the desired emergency
shutdown temperature of the solid
fuel boiler
Temerg SFB/boiler
Emergency shutdown temperature
Adjustment range: 80 ... 105 °C
Factory setting: 95 °C
11. Save
Completing the commissioning
menu
The last menu item of the commission-
ing menu is Save. If you select Save,
all adjustments carried out in the com-
missioning menu will be confi rmed and
saved.
Î In order to confi rm the adjust-
ments made in the commissioning
menu, press button 3
The controller is then ready for opera-
tion with the adjustments made for the
selected system.
The adjustments carried out during
commissioning can be changed after
commissioning anytime in the corre-
sponding adjustment channel.
Additional functions and options can
also be activated or deactivated.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Resol DeltaTherm FK and is the answer not in the manual?