0: Set via the digital operating panel
1: Direct action of the digital operating panel’s potentiometer Kv × (0...5 V)
2: Inverse action of the digital operating panel’s potentiometer Kv × (5...0 V)
3: Direct action of external terminal Kv × (0...5 V)
4: Inverse action of external terminal Kv × (5...0 V)
5: Direct action of external terminal Kv × (0...10 V)
6: Inverse action of external terminal Kv × (10...0 V)
7: Direct action of external terminal Ki × (4...20 mA)
8: Inverse action of external terminal Ki × (20...4 mA)
9: External terminal Kv × (0...5 V) Ki × (4...20 mA) or External terminal Kv ×
(0...10 V) Ki × (4...20 mA)
10: VRC terminal Kv × (-10...+10 V)
11: Kp × (Pulse frequency setting) + Kv × (VRC - 5 V) or Kp × (Pulse frequency
setting) + Kv × (VRC - 2.5 V)
12: External computer frequency setting
b06 setting range:
OFF: User-defined V/f curve
H-00...H-15: Constant torque characteristic
P-00...P-15: Square descending torque characteristic
Bosch Rexroth AG
Parameter Settings
22/31
DOK-RCON01-FE*********-IN04-EN-P