MAINTENANCE
⚠ WARNING ⚠
If you turn OFF the electrical power supply, turn OFF the gas.
⚠ CAUTION ⚠
Eye protection is recommended when cleaning unit.
When any service is completed, ensure that the unit is reassembled correctly so that no unsafe
conditions are created.
When re-lighting, always follow the lighting instructions on the heater.
If any of the original wire supplied with the appliance must be replaced, it must be replaced with
wiring material having a temperature rating of at least 105°C, except for limit control, flame rollout,
and sensor lead wires which must be rated at 150°C.
If replacement parts are required, use only factory-authorized parts.
NOTE: To ensure long life and satisfactory performance, a heater that is operated under normal
conditions should be inspected and cleaned at the start of each heating season. If the heater is
operating in an area where an unusual amount of dust or soot or other impurities are present in
the air, more frequent maintenance is recommended.
The unit is designed to operate with a minimum of maintenance. However, to ensure long life and satisfactory
performance, routine service is recommended. When servicing, follow standard safety procedures and those specific
instructions and warnings in this manual.
Service Checklist
The following section is designed to aid a qualified service person in maintaining and servicing this equipment. At a
minimum, perform the following annually (see Figure 25 for component locations):
Inspect burner/control compartment annually to determine if cleaning is necessary
Clean all dirt, lint, and grease from combustion air opening and venter assembly
Clean all dirt, lint, and grease from fan blade, fan guard, and motor
Clean condensate drain traps
Check heat exchanger both internally and externally
Check burner for scale, dust, or lint accumulation and clean if needed
Check gas valve to ensure that gas flow is being shut off completely
Check vent or vent/combustion air system for soundness and clean openings
Replace any parts that do not appear sound
Check for any damaged wiring and replace as necessary
47
I-UEZ (04-21) 1034347-0

Table of Contents

Other manuals for Reznor APD

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Reznor APD and is the answer not in the manual?

Reznor APD Specifications

General IconGeneral
BrandReznor
ModelAPD
CategoryGas Heater
LanguageEnglish

Related product manuals