EasyManua.ls Logo

Rheem IKONIC RTGH-SR84i - COMMUNICATION, CHIP, AND WIFI ERRORS

Rheem IKONIC RTGH-SR84i
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IKONIC Tankless Water Heater Service Manual
59
ERROR CODE DIAGNOSTICS
ERROR A082
EXPLANATION
Installed Chip Error
This tankless water heater has a gas chip
on the control board. If the gas chip has a
poor connection or the data that gas chip
has is inadequate/wrong, the water heater
displays the “A082” error code on the User
Interface.
Diagnostic check items
Gas chip
Turn Power OFF
Conrm that the correct gas chip is installed.
Insert the correct gas chip.
The chip has a loose connection.
Gas chip appear to be OK.
Remove and reinsert gas chip.
Replace new gas chip.
Is the chip
correct?
Does error code
"A082" appear?
Yes
No
No
Yes