IKONIC Tankless Water Heater Service Manual
70
FLAME AND IGNITER ROD GASKET
HOW TO REMOVE COMPONENTS
1. Remove the hook lm part of the Over Heat Limiter
(OHL ). DO NOT cut the lm.
2. Remove flame and igniter rod wires from the rods.
3. Remove 3 screws from flame and igniter rod bracket,
and pull the flame and igniter rods
4. The gasket is located between the heat exchanger
and flame rod bracket.
NOTE: The spare gasket is located at lower left in the
unit.
Flame Rod
Igniter Rod