14
Z-12 TREATMENT KIT
as the vent outlet. The horizontal breaching of a vent must
The horizontal portions of the vent shall also be supported
for the design and weight of the material employed to
maintain clearances and to prevent physical damage or
separation of joints.
CAT IV
VENT CAP
CAT IV FLUE
MATERIAL
CONDENSATION
TRAP
HEATER UNIT
10' (3 m) OR
LESS
2' (61 cm)
MIN
3' (91 cm)
MIN
Figure 6. Vertical Venting
NOTE:
to connect other types of Category IV vents to the heater.
The supplied vent adapter allows for direct connection
to DuraVent PolyPro, Duravent FasNSeal, Sch 40 PVC
and Sch 40 CPVC.
Termination
The vent terminal should be vertical and should terminate
above the highest point of the roof or building that is within
is maintained) electric meters, gas meters, regulators and
relief equipment.
The distance of the vent terminal from adjacent public
walkways, adjacent buildings, open windows and building
guyed or braced to withstand snow and wind loads.
NOTE: When using PVC Tee vent as termination, insert
the round stainless mesh screens provided with the unit
into the tee ends.
Figure 7. Vertical Venting
APPROVED
UNCONTROLLED DOCUMENT IF PRINTED