28
Control Adjustments
Figure 29. Control Adjustments
Control Panel Removal
To remove the ignition control board from the heater, use
Turn off main power to the heater.
Remove front door to access wire harnesses.
Reaching underneath the ignition board, carefully
remove all connectors and wires from the ignition
board and ON/OFF toggle switch.
Lift the front bezel lid and remove the two lower
Phillips screws.
Carefully lift the control panel upwards and pull away
from the heater.
The control panel can now be flipped around to
remove or inspect the ignition board.
F10343
Figure 30. Removing the Ignition Control Board
Thermostat Operation - Ignition
Control Board
PROGRAM
BUTTON
(SW1)
Figure 31. Ignition Control Board
Controls Operation
The pool heater touchpad, located on the upper portion
of the angled corner panel of the heater, allows the
user to select the mode of operation, adjust the setpoint
diagnostic information. The LCD display window indicates
the water temperature and if applicable the heater setpoint
and current operating condition. A manual power switch
provided turns the control power ON or OFF.
Mode Selection
OFF mode, allowing the LCD display to remain energized
and to continue showing the actual water temperature.
POOL and SPA Modes
In either POOL or SPA mode, the mode, day of week
and time are displayed on the top line of the display. The
current water temperature, desired water temperature
(SETPOINT), and current status are shown alternating on
the lower line of the display. The temperature SETPOINT
In either POOL or SPA modes, the heater will operate to
maintain the desired water temperature, turning the heater
on when the temperature falls below the setpoint and
Filter pump, motorized valve, auxiliary outputs and heating
MANUAL OVERRIDE
APPROVED