32
Display Condition
 
 
Valve Chng Delay 󰀨
High Heating Second stage heat is running with EXT HEAT Aux mode
Heating Heater is operating
Spark Ignition control is running spark
Post Purge 
 
External Heat 
No Demand 
 
 ROM CRC failure on digital control board
 RAM failure on digital control board
 A/D Reference failure on digital control board
 A/D Multiplexor failure on digital control board
Aux Ctrl Fault 8 
 ROM CRC failure on Ignition Control Board
 RAM failure on Ignition Control Board
 A/D failure on Ignition Control Board
 Flame sense circuit failure on Ignition Control Board
 Out of sequence execution detected on Ignition Control Board
 
Remote Error Both Spa and Pool inputs are energized
 
 
Blocked Vent 
Vent Temp Limit Vent Temp Limit switch is open
Clock/Fireman Sw Clock/Fireman switch is open (Not stored in EEPROM)
Air Flow Sw Open Air Pressure Switch open with inducer on
Air Flow Sw Closed 󰀨
󰀨 󰀨
Fan Lockout 
Ignition Failure 
 
Ignition Lockout Ignition trial failed on Propane
MV Output Fault Ignition control has detected problem with gas valve output
Flame w/o CFH 
Low Temp Lockout 
EEPROM Fault Corrupted data found on the Digital Control Board
Ign EEPROM Fault Corrupted data found on the Ignition Control Board
Low Voltage 
Flue Over Temp 󰀨
Flue Sense Fail Flue Monitor is enabled and Flue temperature sensor is open or shorted
Blocked Drain Condensate drain switch is closed
Fan RPM Fault 󰀨
Table N. Error Condition Messages