EasyManua.ls Logo

Ricoh MLP150DN - Page 59

Ricoh MLP150DN
79 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Bulletin PAGE: 7/7
Model: Model AL-C1 Date: 19-Apr-12 No.: RD009064
D. Limitations of the deodorizing filters
The following limitations exist with these filters:
If the temperature of the installation environment is 29C (84.2F) or higher:
z Continuous printing/copying should be limited to a maximum of 38 minutes
z The Auto Off Timer should be set to its default value (60 minutes)
This is because when the temperature is this high, the properties and behavior of the toner change, and
image quality issues begin to occur.

Other manuals for Ricoh MLP150DN

Related product manuals