1.SC Codes
110
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
Replace the Fuser Unit.
Replace the Pressure Roller Cam Position Sensors.
Reconnect the sensor connector.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC570
Fan Error
SC570-00
D
Ozone Exhaust Fan (K)
SC570-01
D
Ozone Exhaust Fan (1st)
SC570-02
D
Ozone Exhaust Fan (2st)
SC570-03
D
Ozone Exhaust Fan (3st)
SC570-04
D
Ozone Exhaust Fan (4st)
SC570-05
D
Ozone Exhaust Fan (5st)
During fan lock detection
Overload
Fan stopped due to foreign object
Connecter disconnected.
Reconnect the connector, or replace the fan
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC571-
00
A
Thermistor disconnection: Pressure Roller Thermistor
Pressure Roller Thermistor detected 0 degree or lower 160 seconds
consecutively after the heater was turned on
Pressure Roller Thermistor disconnection
Connecter contact failure
Replace the Pressure Roller Thermistor.
Reconnect the connector.
Replace the Fuser Unit.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC573-
00
A
Overheat detection (software): Pressure Roller Thermistor
Pressure Roller Thermistor detected 220 degrees or higher 10 seconds
consecutively.
Measurement period: 100 milliseconds
Triac shorted.
IOB board defective.
Fuser Unit controller software runaway
Replace the AC drive board.