1.SC Codes
110
Error Name/Error Condition/Major Cause/Solution
Replace the Pressure Roller Cam Position Sensors.
Reconnect the sensor connector.
Error Name/Error Condition/Major Cause/Solution
During fan lock detection
Fan stopped due to foreign object
Connecter disconnected.
Reconnect the connector, or replace the fan
Error Name/Error Condition/Major Cause/Solution
Thermistor disconnection: Pressure Roller Thermistor
Pressure Roller Thermistor detected 0 degree or lower 160 seconds
consecutively after the heater was turned on
Pressure Roller Thermistor disconnection
Connecter contact failure
Replace the Pressure Roller Thermistor.
Reconnect the connector.
Replace the Fuser Unit.
Error Name/Error Condition/Major Cause/Solution
Overheat detection (software): Pressure Roller Thermistor
Pressure Roller Thermistor detected 220 degrees or higher 10 seconds
consecutively.
Measurement period: 100 milliseconds
IOB board defective.
Fuser Unit controller software runaway
Replace the AC drive board.