1.SC Codes
177
Error Name/Error Condition/Major Cause/Solution
When moving to the home position, home position was not detected within
specified number of pulses. (The first time: jam display, the second time: SC)
When moving from the home position, home position was still detected after
specified number of pulses. (The first time: jam display, the second time: SC)
Motor driver detected an error. (SC from the first time)
Overcurrent to the motor.
Motor drive overheat
Connector disconnected
Replace the Main Board.
Replace the Fold Plate Motor.
Replace the harness.
Re-connect the connector.
Replace the Fold Plate HP Sensor.
Error Name/Error Condition/Major Cause/Solution
Motor driver detected an error. (SC from the first time)
Overcurrent to the motor.
Replace the Main Board.
Replace the 1st Fold Motor.
Replace the harness.
Error Name/Error Condition/Major Cause/Solution
Motor driver detected an error. (SC from the first time)
Overcurrent to the motor.
Motor drive overheat
Replace the Main Board.
Replace the 2nd Fold Motor
Replace the harness.
Error Name/Error Condition/Major Cause/Solution
Motor driver detected an error. (SC from the first time)
Overcurrent to the motor.