1.SC Codes
15
Error Name/Error Condition/Major Cause/Solution
3. Clean the 1st scanner carriage (1stmirror)/2nd scanner carriage (2nd and 3rd
mirror)
4. Replace the LED board on the right sides.
5. Replace the lens brock.
6. Replace the IPU board.
7. Replace the BCU board.
8. Replace the following harnesses:
SBU-IPU/BCU harness
SBU-LED harness.
Error Name/Error Condition/Major Cause/Solution
LED Illumination Adjustment Error (Front)
The LED illumination cannot be adjusted.
This error is detected if the white level peak reached the prescribed threshold
when the white plate was scanned after a specified number of adjustments.
SBU defective
BCU defective
Power/signal harness defective
Check if the SC occurs by turning the power OFF then ON. If the SC occurs again,
do the following steps. Check if the SC reoccurs by cycling the power after each
step.
1. Reconnect the following connectors:
SBU-IPU/BCU harness connector
SBU-LED harness connector
2. Clean or replace the white plate on the exposure glass.
3. Clean the 1st scanner carriage (1stmirror)/2nd scanner carriage (2nd and 3rd
mirror)
4. Replace the LED board on both sides.
5. Replace the lens brock.
6. Replace the IPU board.
7. Replace the BCU board.
8. Replace the following harnesses:
SBU-IPU/BCU harness
SBU-LED harness.
Error Name/Error Condition/Major Cause/Solution
Scanner Home Position Error 1