1.SC Codes
17
Error Name/Error Condition/Major Cause/Solution
This error is detected if the black level did not coverage within prescribed
threshold after a specified number of adjustments.
BCU defective
Power/signal harness defective
Check if the SC occurs by turning the power OFF then ON. If the SC occurs again,
do the following steps. Check if the SC reoccurs by cycling the power after each
step.
1. Reconnect the following connectors:
SBU-IPU/BCU harness connector
SBU-LED harness connector
2. Clean or replace the white plate on the exposure glass.
3. Replace the lens brock.
4. Replace the IPU board.
5. Replace the BCU board.
6. Replace the following harnesses:
SBU-IPU/BCU harness
SBU-LED harness
Error Name/Error Condition/Major Cause/Solution
White level detection error (Front)
The white level cannot be adjusted when the initial adjustments of the CMOS
sensor.
This error is detected if the white level did not coverage within prescribed
threshold after a specified number of adjustments.
SBU defective
LED defective
BCU defective
Power/signal harness defective
Scanner drive error
Condensation in scanner unit
Mirrors or lenses dirty or positioned incorrectly
White plate dirty or installed incorrectly
Check if the SC occurs by turning the power OFF then ON. If the SC occurs again,
do the following steps. Check if the SC reoccurs by cycling the power after each
step.
1. Reconnect the following connectors: