1.SC Codes
218
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC750-
82
D
Perfect Binder: Glue level thermistor error 1
After glue warm-up completed, the glue level thermistor detected a temperature of
over 170 degrees for more than10 sec.
Glue level thermistor defective
Glue heater defective
Slave board defective
Reconnect the connector.
Replace the gluing unit.
Replace the slave board.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC750-
83
D
Perfect Binder: Glue level thermistor error 2
After glue warm-up completed, the glue level thermistor detected a temperature
less than 100 degrees for more than10 sec.
Glue level thermistor defective
Glue heater defective
Slave board defective
Reconnect the connector.
Replace the gluing unit.
Replace the slave board.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC750-
84
D
Perfect Binder: Thermistor disconnect error
The glue abnormal temperature thermistor detected a temperature of less than 5
degrees for 1 sec., or more than 10 sec. after power on. However, if the thermistor
detected less than 100 degrees after measuring temperature at start up,
temperature is checked again after 50 sec.
Glue abnormal temperature thermistor defective
Glue heater defective
Slave board defective
Reconnect the connector.
Replace the gluing unit.
Replace the slave board.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC750-
85
D
Perfect Binder: Glue level thermistor disconnect error
The AD value of the glue level thermistor was above 991 LSB for 10 sec.