1.SC Codes
219
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
Temperature adjustment mode stops if glue level sensor detects the temperature
remaining below 99 degrees for more than 10 sec.
Glue level thermistor defective
Glue heater defective
Slave board defective
Reconnect the connector.
Replace the gluing unit.
Replace the slave board.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC750-
86
D
Perfect Binder: Internal temperature thermostat error
The A/D value of the internal temperature thermostat was detected above 80
degrees for 1 sec.
Internal temperature thermistor defective, Slave board defective
Reconnect the connector.
Replace the internal temperature thermistor.
Replace the slave board.
Replace the thermistor harness.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC750-
87
D
Perfect Binder: Internal temperature thermostat disconnect error
The A/D value of the internal temperature thermostat was detected below -20
degrees for 1 sec.
Internal temperature thermistor defective, Slave board defective
Reconnect the connector.
Replace the internal temperature thermistor.
Replace the slave board.
Replace the thermistor harness.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC750-
88
D
Perfect Binder: Internal temperature thermostat error
Temperature was detected above 10C three consecutive times (sampled every
sec. for 1 min.).
Internal temperature thermistor defective, Slave board defective
Reconnect the connector.
Replace the internal temperature thermistor.
Replace the slave board.