1.SC Codes
220
Error Name/Error Condition/Major Cause/Solution
Replace the thermistor harness.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Glue heater startup error 2
The warm-up temperature was above the +-5C target for the glue vat
temperature. (Not detected within 100 sec. after machine warm-up.)
Internal temperature thermistor defective
Glue heater defective
Slave board defective
Reconnect the connector.
Replace the internal temperature thermistor.
Replace the gluing unit.
Replace the slave board.
Replace the thermistor harness.
Error Name/Error Condition/Major Cause/Solution
Glue heater startup error 3
The warm-up temperature was below the +-5C target for the glue vat temperature.
(Not detected within 100 sec. after machine warm-up.)
Internal temperature thermistor defective
Glue heater defective
Slave board defective
Reconnect the connector.
Replace the internal temperature thermistor.
Replace the gluing unit.
Replace the slave board.
Replace the theristor harness.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Glue heater startup error 4
At the end of temperature adjustment at power on, warm-up did not complete
within 500 sec. The glue vat temperature did not reach the warm-up temperature
within 500 sec.
Glue heater connector loose, broken, defective
Heater defective
Slave board defective
Reconnect the connector.