1.SC Codes
234
Error Name/Error Condition/Major Cause/Solution
Replace the master control board.
Replace the VR harness.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Signature thickness sensor value unstable error
The signature thickness reading did not change, even after the main grip unit
opened and closed.
Signature thickness sensor connector loose, broken, defective
Sensor defective
Reconnect the connector.
Specify the signature thickness again.
Replace the signature thickness sensor.
Replace the master control board EEPROM
Replace the slave control board.
Replace the master control board.
Replace the VR harness.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Glue vat HP sensor late error
The glue vat HP sensor (rear) did not go ON when the glue vat roller motor
initialized at power on and remained on for 4240 ms.
When the glue vat HP sensor (rear) moved from the HP to the front, the glue
vat HP sensor was already OFF.
Glue vat roller motor connector loose, broken, defective
Motor defective
Glue vat HP sensor connector loose, broken, defective
Sensor defective
Reconnect the connector.
Replace the glue vat roller motor.
Replace the glue vat HP sensor.
Replace the slave control board.
Replace the motor harness.
Replace the sensor harness.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Glue vat HP sensor lag error
The glue vat HP sensor did not go off when the glue vat moved to the front, even