1.SC Codes
235
Error Name/Error Condition/Major Cause/Solution
though the glue vat roller motor operated for 285 ms.
The glue vat HP sensor was already ON when the glue vat moved from the front
to the rear.
Glue vat roller motor connector loose, broken, defective
Motor defective
Glue vat HP sensor connector loose, broken, defective
Sensor defective
Reconnect the connector.
Replace the glue vat roller motor.
Replace the glue vat HP sensor.
Replace the slave control board.
Replace the motor harness.
Replace the sensor harness.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Glue vat roller motor error
The glue vat roller rotation sensor could not detect rotation of the glue vat roller
motor within 1200 ms of motor operation.
Glue vat roller motor connector loose, broken, defective
Motor defective
Glue vat roller rotation sensor connector loose, broken, defective
Sensor defective
Reconnect the connector.
Replace the glue vat roller motor.
Replace the glue vat roller rotation sensor.
Replace the slave control board.
Replace the motor harness.
Replace the sensor harness.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Glue roller HP sensor late error
During glue supply, the glue roller HP sensor did not go ON, even though the glue
roller motor was operating for 1000 ms.
Glue supply motor connector loose, broken, defective
Motor defective
Glue pellets jammed
Glue roller HP sensor connector loose, broken, defective