1.SC Codes
241
Error Name/Error Condition/Major Cause/Solution
Reconnect the connector.
Replace the spine fold HP sensor (R).
Replace the spine fold press sensor (R).
Replace the slave control board.
Replace the sensor harness.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Spine fold plate open position late error
At the start of the spine fold operation, the spine plate open sensor did not go ON,
even after the spine plate motor operated for 900 ms (93.75 mm of feed).
Spine plate motor connector loose, broken, defective
Motor defective
Spine open sensor connector loose, broken, defective
Sensor defective
Reconnect the connector.
Replace the spine plate motor.
Replace the spine open sensor.
Replace the slave control board.
Replace the motor harness.
Replace the sensor harness.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Spine fold plate open position lag error
At the start of the spine fold operation, the spine plate open sensor did not go
OFF, even after the spine plate motor operated for 1350 ms (93.75 mm of feed).
Spine plate motor connector loose, broken, defective
Motor defective
Spine open sensor connector loose, broken, defective
Sensor defective
Reconnect the connector.
Replace the spine plate motor.
Replace the spine open sensor.
Replace the slave control board.
Replace the motor harness.
Replace the sensor harness.