To check for any abnormalities in the sensor and motor solenoid, be sure to
perform an input check and output check for them as needed in addition to a visual
check.
1. Reconnect the lift motor.
2. Reconnect the following connector(s).
Lift motor
Lower Limit Sensor
Paper Height Middle Sensor
Paper upper limit sensor 2
3. Replace the following harness(es).
Lift motor
Lower Limit Sensor
Paper Height Middle Sensor
Paper upper limit sensor 2
4. Replace the following electrical component(s).(Paper Tray Lift Mechanism)
Lift motor
Lower Limit Sensor
Paper Height Middle Sensor
Paper upper limit sensor 2
5. Replace the following mechanical component(s).(Paper Tray Lift Mechanism)
Tray bottom plate
Wires
Pulley
Feeler, etc.
6. Replace the Main Control Board of the LCIT.