EasyManua.ls Logo

Ricoh SP 150SUw - SC4 xx: Bias Leak Error Troubleshooting; SC4 xx: Bias Leak Error Details

Ricoh SP 150SUw
82 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Level Definition/ Reset Procedure
C These SC codes are not shown. They are logged internally.
Check the SC error log.
D The SC code is shown in the message on the Status Panel.
Cycle the power OFF/ON.
The SC code will be shown again if the error repeats.
Before deciding to replace a PCB, disconnect the board connectors, and then connect them again.
This is to make sure that the problem was not caused by a bad or loose connection.
SC2xx: Polygon Motor Errors
Code Level Details
202 D Polygon Motor On Timeout Error
No lock signal was received within 10 sec. after the polygon motor was turned
on.
The polygon motor driver I/F harness is loose, broken, or defective.
The polygon motor is broken or defective.
Cycle the power OFF/ON.
Replace the I/F harness.
Replace the polygon motor.
Replace the laser unit.