CutOff temp.
Battery Charger
OFF NOT monitoring external probe for Over Temperature while battery charging.
Value Set in steps
IF Set AND the temperature reaches, or exceeds, the set value:
The output will immediately turn OFF.
The ON/OFF button will turn off it’s illumination,
or react per the setting of ‘External LED’.
Charge Status, on the display, will be set to "CHARGE: t°-OFF", indicating that
the charging cycle was halted due to temperature.
Notes:
- Disabled by setting to 0.
- This setting is only applicable using the (Green) Battery Charging Binding post.
- Should be set to a higher value than the ambient temperature for proper operation.
- ‘CutOff temp’ setting is similar to the ‘OTP (EXT) setting, in that both serve the same
purpose of setting an upper temperature limit.
- However, ‘OTP (EXT) is a global feature,not limited to battery charging. final
safety measure, not specifically for battery charging.
IF ‘CutOff temp AND OTP (EXT)’ are Enabled:
The value of ‘OTP (EXT)’ should be higher value than the ‘CutOff temp’
to ensure proper operation.
CutOff time
Battery Charger
OFF NOT monitoring total time of charge while battery charging.
Settable Range: 00h 01m - 99h 59m.
IF Set,
Battery charging cycle will halt once the set time is achieved.
Note:
This setting is only applicable using the (Green) Battery Charging Binding post.