CutOff temp.
➥Battery Charger
OFF NOT monitoring external probe for Over Temperature while battery charging.
Value Set in 1°steps
IF Set AND the temperature reaches, or exceeds, the set value:
● The output will immediately turn OFF.
● The “ON/OFF” button will turn off it’s illumination,
○ or react per the setting of ‘External LED’.
● Charge Status, on the display, will be set to "CHARGE: t°-OFF", indicating that
the charging cycle was halted due to temperature.
Notes:
- Disabled by setting to 0.
- This setting is only applicable using the (Green) Battery Charging Binding post.
- Should be set to a higher value than the ambient temperature for proper operation.
- ‘CutOff temp’ setting is similar to the ‘OTP (EXT)’ setting, in that both serve the same
purpose of setting an upper temperature limit.
- However, ‘OTP (EXT)’ is a global feature,not limited to battery charging. final
safety measure, not specifically for battery charging.
IF ‘CutOff temp’ AND ‘OTP (EXT)’ are Enabled:
The value of ‘OTP (EXT)’ should be higher value than the ‘CutOff temp’
to ensure proper operation.
CutOff time
➥Battery Charger
OFF NOT monitoring total time of charge while battery charging.
Settable Range: 00h 01m - 99h 59m.
IF Set,
Battery charging cycle will halt once the set time is achieved.
Note:
This setting is only applicable using the (Green) Battery Charging Binding post.