20051011
44
GB
Operation, indication, diagnostics
7.6 Manual restore
Tab. AB
Press and simultaneously for >1 second (Escape) for starting the manual restore process. Pa-
rameter PrC appears.
Display: PrC
Press and for parameter rSt.
Display: rSt
run appears during download (restore process) of program sequence.
After the restore process, the unit is automatically in the lockout position (LOC 138) and must be
reset for operation!
After 2 minutes, the unit changes to Loc 138
After the restore process, the unit is automatically in the lockout position (LOC 138) and must be
reset for operation!
Press for >1 second to reset the unit.
Display: OFF
-
and
+
> 1s
- +
-
or
+
-
+
nfo
1...3s
Alternately
Alternately
nfo
> 1 s
nfo