7
20163082
Technical description of the burner
4.1 Burner designation
4.2 Models available
Tab. A
4 Technical description of the burner
Designation Voltage Start-up Code
RS 810/EV BLU 3/400/50 Inverter 20160292
Class 3 EN676
Range: R
Size
Fuel: Natural gas
Light oil
Light oil / Methane
Adjustment:
Flame control system:
FS1
FS2
Standard (1 stop every 24h)
Continuous operation (1 stop every 72h)
Electrical supply of the system:
3/400/50
3/230/50
Voltage of auxiliaries:
230/50/60
110/50/60
R S 810 EV TC
Emission:
C01 or... Class 1 EN676
C02 or MZ Class 2 EN676
C03 or BLU Class 3 EN676
FS1/FS2
3/400/50 230/50/60
BASIC DESIGNATION
EXTENDED DESIGNATION
BLU
3N / 400V / 50Hz
3 / 230V / 50Hz
230V / 50-60Hz
110V / 50-60Hz
Heavy oil
E Electronic cam
EV Electronic cam with variable speed (with Inverter)
P Proportional air/gas valve
BP Two stage (light oil) / Proportional valve (gas)
M Mechanical cam
S
L
LS
N
Head:
TC Standard head
TL Long head
C03 or MX
C05
Class 5 EN676 (NOx < 56 mg/kWh)
*The burner leaves the factory set up for FS1 op-
eration. If FS2 operation is required, see section
“Modify the parameter for continuous/intermittent
operation (FS2/FS1)” on page 36..