Example 5: To Generate a Linear Sweep Wave
Target: Generate a sweep sine wave with 100 Hz to 10 kHz frequency, internal trigger,
linear mode and 1 s sweep time.
How to realize via commands?
0 *IDN? /* Query ID to check the operating state */
1 FUNC SIN /* Select the sweep function */
2 SWE:STAT ON /* Enable frequency sweep */
3 SWE:SPAC LIN /* Select linear sweep mode */
4 FREQ:STAR 100 /* Set the start frequency */
5 FREQ:STOP 10000 /* Set the stop frequency */
6 SWE:TIME 1 /* Set the sweep time */
7 TRIG:SOUR IMM /* Select internal trigger source */
8 OUTP ON /* Enable the [Output] connector of CH1 at the
front panel */