RIGOL Command Systems
Programming Guide for DS1000B Series
2-110
1. :CURSor:MODE
Command Format:
:CURSor:MODE <mode>
:CURSor:MODE?
Function:
The command sets the cursor mode. The <mode> may be CLOSe, MANUal,
TRACk or MEASure (measure automatically).
Returned Format:
The query returns CLOSE or MANUAL, TRACK, MEASURE.
Example:
:CURS:MODE TRAC Set the cursor mode as track.
:CURS:MODE? Return TRACK.
2. :CURSor:MANUal:TYPE
Command Format
:CURSor:MANUal:TYPE <type>
:CURSor:MANUal:TYPE?
Function:
The command sets the cursor type of manual cursor. The <type> may be TIME
or AMPlitude.
Returned Format:
The query returns Time or Amplitude.
Example:
:CURS:MANU:TYPE TIME Set the cursor type of manual cursor as time.
:CURS:MANU:TYPE? Return Time.
3. :CURSor:MANUal:SOURce
Command Format: