EasyManuals Logo

Rigol DS1000B Series Programming Guide

Rigol DS1000B Series
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #78 background imageLoading...
Page #78 background image
RIGOL Command Systems
Programming Guide for DS1000B Series
Example:
:MEAS:TOT ON Set the total measurement function on.
:MEAS:TOT? Return 1.
25. :MEASure:SOURce
Command Format:
:MEASure:SOURce <source>
:MEASure:SOURce?
Functions
The command selects the measurement channel. The <source> may be
CHANnel1, CHANnel2, CHANnel3 or CHANnel4.
Returned Format:
The query returns CH1 or CH2, CH3, CH4.
Example:
:MEAS:SOUR CHAN1 Measure the signal from CH1.
:MEAS:SOUR? Return CH1.
26. :MEASure:DELAySOURce
Command Format:
:MEASure:DELAySOURce <source>,<source>
:MEASure:DELAySOURce?
Functions
The command selects the channel for measuring the time delay. The< source>
may be CHANnel1, CHANnel2, CHANnel3 or CHANnel4.
Returned Format:
The query returns CH1, CH2 or CH1, CH3, CH1, CH4, CH2, CH3, CH2, CH4, CH3,
CH4.
Example:
:MEAS:DELASOUR CHAN1 CHAN2 Measure the delay source.