6 | Linear ue installation guide 13541-A 01-20
Flueing options
For lowest cost, optimal performance, ease of installation and servicing, Rinnai
recommend short ue installations (less than 3 m) are considered before all other
options. Short ue installations are shown below.
300 mm min.
up to 3 m
300 mm min
300 mm Min
E
SPIPE9
0
0
ESWTERM
45° bends
LSFKIT01
ASPDFK
45° bends
E
SPIPE9
0
0
ESWTERM
ESWTERM
ESPIPE900
LSFKIT01
ASPDFK
LSFEXTKIT01
The gas pressures of the Linear are factory set for short ue installations (less than 3 m).
Installations greater than 3 m are long ue installations and will require a dip switch change, refer
commissioning instructions.
When considering the location of the re care must be taken to ensure the ue path is free from
obstructions such as studs, noggins, joist, braces, electrics etc.