EasyManua.ls Logo

Rinnai SUNMASTER - Gas Booster Location and Mounting; Water Pipe Installation Guidelines; Water Supply Requirements

Rinnai SUNMASTER
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Rinnai Australia - 16 - Solar Split Systems Operating / Installation Manual- Version 8 - 18/10/10
Table 4 - Specifications - Gas Boosters
Model Name: S20 S26
Boost Capacity:
- L/min. @ 20°C rise
- L/min @ 25°C rise
(L/min)
20
16
26
24
Maximum Rated Flow: (L/min) 20 26
Minimum Supply Pressure for Maximum rated flow:
(1)
(kPa) 120 200
Minimum Flow for Operation: (L/min) 2.4 2.4
Frost Protection: Yes Yes
Gas Consumption (Maximum / Minimum): (MJ/hr.) 125 - 18 188 - 23
Star Rating (AS 4552 - 1998): 5.5 5.0
Hot Water Delivery Temperature:
(2)
60°C 60°C
Dimensions: Height x Width x Depth: (mm) 530 x 350 x 194 530 x 350 x 194
Weight: (Kg) 15 21
(1) - Units will operate at lower pressures but the rated flow with not be achieved.
(2) - Gas boosters for Solar hot water applications should be preset to deliver a minimum temperature of 60°C.
Gas boosters factory pre set to 60°C or 65°C will be marked as such. If there are no temperature markings on the water
heater, on site conversion is required. This is a simple procedure, contact your Service Agent.
SPECIFICATIONS FOR GAS BOOSTERS