EasyManua.ls Logo

RITEC RPR-4000 - Page 9

RITEC RPR-4000
51 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RPR-4000
Operations manual
REV 8-21 9
Receiver
Multiplexed Receiver Inputs ..................................................2 ea.
Frequency Range (LF model) ................................................50 kHz to 20MHz
Frequency Range (HF model) ................................................200 kHz to 20MHz
Frequency Range (VHF model) .............................................200 kHz to 95MHz
Nominal Input Impedance (both inputs) ................................50 Ω
Minimum Gain .......................................................................20 dB
Maximum Gain1 ....................................................................100 dB
Gain Control Range ...............................................................80dB in 0.4dB steps
Maximum Output Level .........................................................1 V peak to peak into 50 Ω
Output Impedance ..................................................................50 Ω
LF model
High Pass Filters ....................................................................50, 100, 200, 400, 800 kHz,
........................................................................2, 4, and 8 MHz
Low Pass Filters .....................................................................100, 200, 500 kHz, 1.5, 2.5,
........................................................................6, 12 and 22 MHz
HF model
High Pass Filters ....................................................................200, 400, 800 kHz, 2, 4, 8,
........................................................................18 and 45 MHz
Low Pass Filters .....................................................................700 kHz, 1.5, 2.5, 6, 12, 27,
........................................................................55 and 100MHz
Keypad and Display
Keypad ...................................................................................4 by 4 tactile feedback
membrane
Display ...................................................................................4 rows by 20 character
backlit LCD
Power Requirements
Power Input ............................................................................95-125 VAC or 195-250
VAC,
50-60 Hz, 300VA max
Packaging
Enclosure................................................................................Bench top, 19” Rack
compatible
(4U x 19”)
Enclosure Ingress ..................................................................IP20
Enclosure Impact Rating ........................................................IK08