13. ERROR MESSAGES
The Power Peak® C8 EQ-BID is fitted with safety circuits designed to ensure that the
charge or discharge process is completed reliably and safely. If an error should occur, a
corresponding message appears on the screen, and the piezo buzzer emits a shrill warning
sound. The following error messages may be displayed: once the fault has been corrected,
pressing any button turns the error message off again.
Input voltage below 10.5 V
Incorrect cell count
The data on the BID chip or key cannot be processed
by the Power Peak® C8 EQ-BID, e.g. Lithium cell
count > 8 cells.
Corrupt data on the BID chip or key. If this should
happen, you must re-edit the BID data. When you
press any button to cancel the error message, the
“EDIT DATA” menu is opened automatically; the bat-
tery data must now be re-entered.
Charger overheating!
The reason may be a faulty cooling fan or a blocked
vent grille. To test this, disconnect the battery and
switch the charger off, then switch the unit on again, re-connect the battery, and briefly start
a discharge process: if the fan does not immediately start running, disconnect the battery
and switch the charger off without delay. Send the defective charger to a robbe Service
Centre for repair (please note the guarantee requirements: chapter 17 on page 21).