Robin RGV2200 - No DC Output

Robin RGV2200
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
-4
NO
DC OUTPUT
11-4-1 CHECK THE AC OUTPUT.
Check the generator by following Step
11-1-1
through Step
11-1-3.
114-2 CHECK THE DC BREAKER.
If
the DC breaker turned
off
while charging a
battery, check the cables for short-circuit or
connection in reverse polarity before resetting
it
on.
NOTE
:
If the DC output is used
to
charge a
large capacity battery
or
an over-dis-
charged battery, an excessive current
may flow causing.
11-4-3 CHECK THE
WIRING.
Check all the wires to be connected correctly.
11-44 CHECK THE DIODE RECTIFIER.
Remove the control panel and che-ck the diode
rectifier with a circuit tester.
Refer to Section
9-7
"DIODE RECTIFIER'' for the
checking procedure.
11-4-5 CHECK THE DC COIL
I
I
Fig.
17-10
Check the resistance between two brown leads from stator with a circuit tester.
I
MODEL SPECIFICATION
I
RESISTANCE
I
i
50Hz
!
11 OV. 220V. 240V, 11 OVl22OV
0.3652
i
60Hz
i
120V, 220V, 11 OV/22OV, 12OVl24OV 0.32R
I
RGV2200
I
i
50Hz
1
110V. 220V, 240V. 110V/220V
1
0.260
:
60Hz
I
120V. 220V, 110V/220V. 120Vi240V
1
0.21
0
RGV2600
~
:
50Hz
;
1 1 OV. 220V, 240V. 11 OV!220V 0.24R
60Hz
i
120V. 220V, 11 OVi22OV, 12OVl24OV
5OHz
0.200
0.150
1 1 OV. 220V, 240V,
1
1 OVi22OV
8
60Hz
I
120V. 220V. 11 OVl22OV. 120V/240V 0.13R
RGV4000
:
RGV6000
Table
11-3
If
the resistance reading is much larger
or
smaller than the specified value, the DC coil
of
the stator
is
faulty. Replace stator with a new one.
-
63
-