37
MAINTENANCE
Precautions
●
Installation and maintenance of the gas
boiler must be performed by the installer/
engineer according to the operation
instructions of the manufacturer and local
current standard operation rules.
Note:
The installer/engineer must be Gas Safe
registered for installation and maintenance of
domestic heating and hot water appliances.
●
Any maintenance must only be performed
by a Gas Safe registered installer/engineer and
can only use original components from the
manufacturer.
●
If the ownership of the appliance is
transferred, or the appliance is moved or
reinstalled, the <User’s guide> and <Manual
for installation and maintenance> should
accompany the appliance.
●
All accessories of the appliance should
be the original components from the
manufacturer or the manufactures warranty
will be void.
●
The appliance should be only used for
domestic heating and hot water just as
indicated in User’s guide.
●
The manufacturers will not take any
responsibility for any property loses and
persons harmed caused by incorrect
installation and operation.
●
Do not use the appliance if a problem
emerges during installation and operation,
please contact the supplier or local after-sales
service department.
●
Please use a wet cloth and soapy water
to clean the externals of the appliance. Other
cleaning liquids should not be used.
Anti-freeze function
The gas boiler has anti-freeze function.
If the gas and power is on, the boiler will start
to work automatically when the heating water
temperature is below 5
°C
, and heat the water
in the system to about 30
°C
.
Warning!
The anti-freeze function may not ensure water
will circle the whole heating system.
If the gas boiler stop running for several
hours in very cold weather, it may lead to the
system becoming frozen. If you are not at
home during freezing period, be sure to keep
the heating function running, and keep the
temperature of every room above the freezing
point.
However, when there is some external failure,
such as gas or, power outage or air exhaust
system are abnormal, the inner inspection
device will turn off the boiler automatically,
so it can’t protect against freezing. To avoid
such situation, if there are no people at home
for long periods, you may ask the installer/
engineer to drain out the water in heating
system and gas boiler.
Warning!
When the gas boiler is executing the anti-
freeze function, it may need to conduct
combustion work. So the gas supply must be
sure smooth and water in the heating system.