Do you have a question about the Roche ACCU-CHECK Active and is the answer not in the manual?
Type | Blood Glucose Meter |
---|---|
Measurement Range | 10-600 mg/dL |
Sample Size | 0.6 µL |
Display | LCD |
Data Transfer | No |
Operating Conditions | 10-40 °C, 10-90% relative humidity |
Memory Capacity | 500 test results |
Weight | Approximately 50 g |
Blood Sample | Capillary blood |
Automatic Shut Off | Yes |
Test Time | 5 seconds |
Overview of key functionalities including fast testing, ergonomic design, small sample size, and data analysis capabilities.
Explains the purpose of the manual and introduces symbols used for warnings and important information.
The primary operational mode for performing blood glucose tests using the meter.
Enables retrieval, averaging, and management of stored blood glucose results.
Allows users to configure settings such as date, time, and beep tone.
Instructions for preparing the meter for its first use, including battery activation and compartment closure.
Guide to setting essential parameters like date, time, and display format for initial meter setup.
Explains the process of matching test strips to the meter using coding chips for accurate readings.
Lists the necessary items required to perform a blood glucose test with the meter.
Provides steps for proper preparation, including hand washing and test strip handling.
Detailed, step-by-step instructions for conducting a blood glucose measurement.
Details the meter's capacity to store up to 200 results with date and time.
Instructions on how to access stored blood glucose readings and calculate averages.
Guidance on transferring test results from the meter to a computer for analysis.
Procedures for performing quality control tests to ensure meter accuracy.
Lists items needed and preparation steps for quality control tests.
Step-by-step guide for conducting quality control tests and interpreting results.
Procedure to verify the correct functioning of all elements on the meter's display.
Guidelines for routine cleaning of the meter and its components to maintain performance.
Specific cleaning and disinfection protocols for professional settings, including infection risks.
Information on battery performance, replacement procedure, and disposal.
Details on temperature, light, and humidity affecting meter accuracy and storage.
Introduction to the types of messages and symbols the meter may display.
Detailed explanations of various messages and symbols encountered during meter operation.
Guidance on identifying and resolving specific error messages (E-1 to E-9, ---, EEE, Err, ttt).
A checklist to help diagnose and resolve common issues leading to implausible results or errors.
Overview of the Accu-Chek Softclix finger pricker for obtaining blood samples.
Identification of the various parts and components of the Accu-Chek Softclix finger pricker.
Instructions on how to adjust the lancet penetration depth for optimal blood sampling.
Step-by-step guide for the safe and effective operation of the finger pricker.
Procedures for cleaning and disinfecting the Accu-Chek Softclix device.
Provides detailed specifications, including meter type, test principle, and operating conditions.
Information on recommended test strips, control solutions, and lancets for the system.
Details the terms and conditions of the product's warranty and guarantee.
Contact information and procedures for obtaining customer support and technical service.