24 Rockwell Automation Publication 440G-UM001C-EN-P - June 2019
Chapter 4 Wiring
Table 7 - Lock Status Auxiliary Power to Release
Table 8 - Lock Status Auxiliary Power to Lock
Table 9 - Door Proximity Auxiliary Power to Release
Table 10 - Door Proximity Auxiliary Power to Lock
Inputs Outputs
Door Lock Control OSSD Input Lock Status AUX OSSD Output
Open Off or On High or Low Unlocked High 24V Low 0V
Closed Off 0V Low 0V Locked Low 0V Low 0V
Closed On 24V Low 0V Unlocked High 24V Low 0V
Closed Off 0V High 24V Locked Low 0V High 24V
Closed On 24V High 24V Unlocked High 24V Low 0V
Inputs Outputs
Door Lock Control OSSD Input Lock Status AUX OSSD Output
Open Off or On High or Low Unlocked High 24V Low 0V
Closed Off 0V Low 0V Unlocked High 24V Low 0V
Closed On 24V Low 0V Locked Low 0V Low 0V
Closed Off 0V High 24V Unlocked High 24V Low 0V
Closed On 24V High 24V Locked Low 0V High 24V
Inputs Outputs
Door Lock Control OSSD Input Lock Status AUX OSSD Output
Open Off or On High or Low Unlocked High 24V Low 0V
Closed Off 0V Low 0V Locked Low 0V Low 0V
Closed On 24V Low 0V Unlocked Low 0V Low 0V
Closed Off 0V High 24V Locked Low 0V High 24V
Closed On 24V High 24V Unlocked Low 0V Low 0V
Inputs Outputs
Door Lock Control OSSD Input Lock Status AUX OSSD Output
Open Off or On High or Low Unlocked High 24V Low 0V
Closed Off 0V Low 0V Unlocked Low 0V Low 0V
Closed On 24V Low 0V Locked Low 0V Low 0V
Closed Off 0V High 24V Unlocked Low 0V Low 0V
Closed On 24V High 24V Locked Low 0V High 24V