PR311 v1.0 fv102 EN Rev.E.DOC 10/22/2007
6
3.4 Stand-alone Operation
In this case the PR311 access controller autonomously supervises door passage and doesn’t require any
connection to the Host device. All users belong to the same group which has permanent access authorization
regardless of time. Neither the Identification Mode nor Door Mode can be controlled by time schedules, events
are not registered.
4 F UNCTIONAL D ESCRIPTION
4.1 Users
The PR311 can register up to 1000 users. Every user has its ID (identification) number from 001 to 999 and
may have its card and PIN. The PR311 controller precludes assignment of the same cards or PINs for 2 different
users. Users can be identified by cards, PINs or both methods simultaneously. The PIN codes may have from 3
to 6 digits and whenever entered must be followed by [#] mark which is used to mark the end of a code.
The PR311 controller supports five types (classes) of users: MASTER, INSTALLER, NORMAL, TOGGLE and
TOGGLE LTD. Each of the class has different authorization for programming, unlocking and rearming of a
controller.
Table 1: User types
User Type ID number Description
INSTALLER No ID Authorization for entry to the Installer Programming only.
MASTER 000 Authorization for user programming commands, unlocking and rearming.
TOGGLE ID=01…49 Authorization for unlocking and rearming.
TOGGLE LTD ID=50…99 Authorization for rearming only.
NORMAL ID=100…999 Authorization for unlocking only.
Note: By default each User Programming Command requires the MASTER identifier; nevertheless installer can
clear this request for some or for all of User Commands.
4.2 Group of Users
When the PR311 controller operates in the stand-alone mode all users programmed to a unit belongs to the
same group of users, as a result they have the same access authorization (i.e. access level) which doesn’t
depends of a time - all users programmed to a unit have access to a controlled door.
When the PR311 controller is a part of Integrated Access Control System controlled by the Host device, all the
users can be divided into 256 groups and may have different access authorization. The access level of each
group can be controlled by time schedule, the PR311 allows up to 32 different time schedules to be defined for
a unit.
4.3 User Identification
The PR311 recognize the users by means of theirs identifiers. Each user programmed to the controller may
have card and/or PIN. The method which controller uses for user identification depends on the actual
Identification Mode. The Identification Mode determines which kind of identifier (card, PIN or both) a user must
use in order to be accepted by the controller. The PR311 enables following identification methods:
Card only: controller accepts only cards
PIN only: controller accepts only PINs
Card or PIN: controller requires card or PIN, only one of them is necessary for a successful identification
Card and PIN: controller requires card and PIN, both of them are necessary for a successful
identification.
Note: For Card and PIN mode user must read its card and enter its PIN, sequence doesn’t matter.