EasyManua.ls Logo

Rohde & Schwarz NGMO1 - Page 19

Rohde & Schwarz NGMO1
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Unit Description Power Supply NGMO
4.00 / 07-2004 3-5
deviation from full scale 10 mA 10 mA
with ±10 % AC supply variation
1 mA 1 mA
from 10 to 90 % load change 2.5 mA 2.5 mA
current sink capability 2.8 A (0 to 5 V) derating up
to 1 A at 15 V
2.8 A (0 to 5 V) derating up
to 1 A at 15 V
Voltage measurement
- Range -5 to 25 V -5 to 25 V
resolution 1 mV 1 mV
deviation from full scale 0.03 % +3 mV 0.03 % +3 mV
- Measurement time 2 ms to 200 ms settable 2 ms to 200 ms settable
averaging 1 to 10 values 1 to 10 values
Current measurement
- Ranges 7 A/0.5 A/5 mA 7 A/0.5 A/5 mA
resolution 200 µA/10 µA/0.1 µA 200 µA/10 µA/0.1 µA
deviation from full scale 15 mA/1 mA/10 µA 5 mA/1 mA/10 µA
- Measurement time 2 ms to 200 ms settable 2 ms to 200 ms settable
averaging 1 to 10 values 1 to 10 values
Dynamic measurement
- Sample buffer 1 to 5000 points 1 to 5000 points
- Sample time 10 µs to 1 s in 10 µs steps 10 µs to 1 s in 10 µs steps
- multiple trigger 1 to 100 1 to 100
- Triggering system
ranges 5 A/0.5 A 5 A/0.5 A
settable levels
range 5 A 0 A to 7 A in 200 µA steps 0 A to 7 A in 200 µA steps
range 0.5 A 0 mA to 0.5 A in 10 µA
steps
0 mA to 0.5 A in 10 µA
steps
DVM -5 V to 25 V in 1 mV steps -5 V to 25 V in 1 mV steps