Power Supply NGMO IEEE Commands
5-6 4.00 / 07-2004
5.3  OUTPut command summary
Com-
mand
Parameter Par. value Description Def. SCPI
:OUT [:A] <CHAR_VAL> OFF Turns output A off OFF
<CHAR_VAL> ON Turns output A on
:OUT :B <CHAR_VAL> OFF Turns output B off OFF
<CHAR_VAL> ON Turns output B on
:OUTPut [:A] Channel A /
Channel 1
:OUTPut
[1]
Channel A /
Channel 1
:OUTPut :B Channel B /
Channel 2
:OUTPut2 Channel B /
Channel 2
[:STATe] <CHAR_VAL> Turns output ON or
OFF (A or B)
OFF
9
OFF Turns output off
ON Turns output on
MIN Turns output off
* DEFault Turns output off
MAX Turns output on
DISPlay Sets LCD to main
screen
[:STATe]? <CHAR_VAL> Queries state of
output
Results:
OFF
ON
MIN OFF
DEFault OFF
MAX ON
:OPEN-
sense
<CHAR_VAL> OFF Turns open sense
detection off
ON Turns open sense
detection on
MIN Turns open sense
detection off
DEFault Turns open sense
detection on
MAX Turns open sense
detection on
:OPEN-
sense?
<CHAR_VAL> Queries of open
sense detection
setting
OFF
ON
MIN OFF
* DEFault ON
MAX ON