Power Supply NGMO IEEE Commands
5-28 4.00 / 07-2004
5.9 Signal-oriented measurement-command sum-
mary
Com-
mand
Parameter Par. value Description Def. SCPI
:FETCh [:A]? Channel A /
Channel 1
:FETCh[1]
?
Channel A /
Channel 1
:FETCh :B? Channel B /
Channel 2
:FETCh2? Channel B /
Channel 2
Returns the last
triggered reading.
Measuremode is
taken from last
"SENSe:FUNC-
tion" setting.
:FETCh [:A] Channel A /
Channel 1
:FETCh[1] Channel A /
Channel 1
:FETCh :B Channel B /
Channel 2
:FETCh2 Channel B /
Channel 2
:ARRay? Returns the last
array of triggered
readings. Return
values are always
sampling points.
:READ [:A]? Channel A /
Channel 1
:READ[1]? Channel A /
Channel 1
:READ :B? Channel B /
Channel 2
:READ2? Channel B /
Channel 2
Triggers and
returns a reading.
Measuremode is
taken from last
"SENSe:FUNC-
tion" setting
:READ [:A] Channel A /
Channel 1
:READ[1] Channel A /
Channel 1
:READ :B Channel B /
Channel 2
:READ2 Channel B /
Channel 2
:ARRay? Triggers and
returns a array of
readings. Return
value are always
sampling points.