EasyManua.ls Logo

Rohde & Schwarz NGMO1 - Local Sense; Output Impedance; Fig. 4-3 Local Sense Connections

Rohde & Schwarz NGMO1
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation Power Supply NGMO
4.00 / 07-2004 4-21
4.3.2 Local sense
Fig. 4-3 Local sense connections
The NGMO2 can be connected to operate with local sense leads
(2- wire connection) as shown in Fig. 4-3. When this connection sche-
me is used the sense inputs and supply outputs are jumpered at the
rear of the NGMO2.
4.3.3 Output Impedance
The NGMO2 has a variable output impedance feature on both chan-
nels. This output impedance setting allows the performance of the bat-
tery channel to closely model a real battery’s performance with a dy-
namic load. When setting the output impedance to a certain value (R
I
),
the output voltage drop will be proportional to the output current (see
formula below). The output voltage will be reduced by the voltage drop.
Voltage drop equation: V
drop(t) = R
I
x I(t)