Power Supply NGMO IEEE Commands
5-10 4.00 / 07-2004
Com-
mand
Parameter Par. value Description Def. SCPI
LOW or
0.005[A]
5mA
AUTO Auto ranging
MIN Auto ranging
* DEFault 5A
MAX 5mA
DISPlay Sets LCD to:
CURRENT
RANGE
:CURRent [:DC] :RANGe [:UPPer]? <CHAR_VAL> Queries current
range
HIGH
MEDIUM
LOW
AUTO
MIN AUTO
DEFault HIGH
MAX LOW
:MEASure :INTerval <CHAR_VAL> or
<NUM_VAL>
Sets the measure-
ment interval for
voltage and
current
1
2.00E-03 Measurement
interval = 2 ms
2.00E-01 Measurement
interval = 200 ms
MIN 2 ms
* DEFault 10 ms
MAX 200 ms
DISPlay Sets LCD to
STATIC
MEASURE
INTERVAL
:MEASure :INTerval? <CHAR_VAL> Queries measure-
ment interval
Results:
2E-3 <=
NUM_VAL <= 0.2
MIN 0.002 ms
DEFault 0.01 ms
MAX 0.2 ms
:AVERage [:COUNt] <CHAR_VAL> or
<NUM_VAL>
Sets the measure
average count
1
1 Average count = 1
10 Average count =
10
MIN 1
* DEFault 1
MAX 10