IEEE Commands Power Supply NGMO
4.00 / 07-2004 5-15
Com-
mand
Parameter Par. value Description Def. SCPI
DEFault 1.00
MAX 5000.00
:PULSe :TRIGger :OFFSet <CHAR_VAL> or
<NUM_VAL>
Sets trigger offset 0
-5000 Trigger offset
-5000
50000 Trigger offset
50000
MIN Trigger offset
-5000
* DEFault Trigger offset 0
MAX Trigger offset
50000
DISPlay Sets LCD to
TRIGGER
OFFSET
:PULSe :TRIGger :OFFSet? <CHAR_VAL> Queries trigger
offset
0
Results:
-5000 <=
NUM_VAL <=
50000
MIN -5000.00
DEFault 0.00
MAX 50000.00
:PULSe :TRIGger :COUNt <CHAR_VAL> or
<NUM_VAL>
Sets trigger count 1
1 Trigger count 1
100 Trigger count 100
MIN Trigger count 1
* DEFault Trigger count 1
MAX Trigger count 100
DISPlay Sets LCD to
TRIGGER
COUNT
:PULSe :TRIGger :COUNt? <CHAR_VAL> Queries trigger
count
Results:
1 <= NUM_VAL
<= 100
MIN 1.00
DEFault 1.00
MAX 100.00
:PULSe :TRIGger :TIMeout <CHAR_VAL> or
<NUM_VAL>
Sets trigger
timeout
INFI-
NITE
0.001 Triggers timeout
0.001 sec.
60 Triggers timeout
60 sec.
INFinite Triggers timeout
infinite

Other manuals for Rohde & Schwarz NGMO1