Remote control commands
R&S
®
RTE
1600User Manual 1326.1032.02 ─ 20
Suffix:
<n>
.
1..4
1 if trigger type is DATA or WINDow
Specifies the condition number if trigger type is CONDition:
– 1 | 2 for I²S standard, left- und right-justified data formats
– 1 | 2 | 3 | 4 for TDM signals
Parameters:
<DataCondition> OFF | ANY | EQUal | NEQual | LTHan | LETHan | GTHan |
GETHan | INRange | OORange
OFF = ANY
No range is defined.
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
Equal, Not equal, Less than, Less or equal than, Greater Than,
Greater or equal than. These conditions require one data pattern
to be set with TRIGger<m>:I2S:TCONdition<n>:DMIN.
INRange | OORange
In range, Out of range: Set the minimum and maximum value of
the range with TRIGger<m>:I2S:TCONdition<n>:DMIN and
TRIGger<m>:I2S:TCONdition<n>:DMAX.
*RST:
OFF
TRIGger<m>:I2S:TCONdition<n>:DMIN <DataMinPattern>
Specifies a data pattern, or sets the the start value of a data pattern range.
Suffix:
<n>
.
1..4
1 if trigger type is DATA or WINDow
Specifies the condition number if trigger type is CONDition:
– 1 | 2 for I²S standard, left- und right-justified data formats
– 1 | 2 | 3 | 4 for TDM signals
Parameters:
<DataMinPattern> Numeric pattern in 2's complement format. See also: Chap-
ter 18.4.6, "Bit pattern parameter", on page 1076
X bits are not allowed. If the bit string is shorter than the word
length, the rightmost bit of the input bit string is aligned to the
rightmost (LSB) bit of the word.
TRIGger<m>:I2S:TCONdition<n>:DMAX <DataMaxPattern>
Sets the the end value of an data range if the operator TRIGger<m>:I2S:
TCONdition<n>:CONDtion is set to INRange or OORange.
Protocols