64
Jun. 2005
10.LCD check
This test checks the LCD for damaged dots.
1. Press the [Full 1] button in the lower section to check that the entire
screen turns off.
2. Press the [Full 2] button in the lower section to check that the entire
screen turns on.
3. Check each color when you press [Full 3] in the lower section.
4. Turn [LCD Contrast Volume] in the jack panel from maximum to
minimum, and confirm contrast changed from bright to dark.
And at the end set the volume center.
5. Press the [Drums/SFX] button to proceed to the next item.
11.Set LCD calibration of touch panel
This test aligns (calibrates) the touch panel using the touch pen (P/
No.00900545).
Using the touch pen, touch the square mark at the left bottom corner on the
LCD.
Recognizing the touch, another square mark appear at the next point. touch it
similarly. Calibration completes when you touch all the four corner on the
screen.
12.Destination region setting
1. Press the following button:
Example
fig.test-volte
2. Press the [Drums/SFX] button to proceed to the next item.
13.Initialize the rhythm stored in the [Disk/
User] button
fig.test-rhythm
Press the [Drums/SFX] button to restore the rhythms stored in the [Disk/
User] button.
Or press the Arranger Section [Start/Stop] button to skip the initialization.
fig.test-rhythm-2
14.Version and Destination region setting
check again
Example
fig.ver1
Press the [Drums/SFX] button to proceed to next.
15.Exiting test mode
fig.test-end
To exit test mode, turn off the power.
Destination Voltage area Button
US: 117V area: Lower section [Full 1]
EXP: 230/240V area: Lower section [Full 2]
DOM: 100V area: Lower section [Full 3]