22
5. Troubleshooting
Error Message Remark
#1 Command Not When an unrecognizable command is transmitted, that command is ignored.
Recognized
#2 Wrong Number When the number of parameters supported by a command is incorrect, that
of Parameters command is ignored.
#3 Out of When a parameter value is outside that parameter's range, it is ignored.
Parameter Range
#5 Unknown When a character set code not included in the current character set is specified, that character
Character Set
is ignored. Use [Character] on the menu to search for available character set codes.
#6 Position The overflow positions are ignored.
Overflow
#7 Polygon Buffer The overflow was ignored.
Overflow
#10 Output When executing an output request command, another output request command was sent (only
Request Overlap
the first one received is effective).
#11 I/O Command When a device control command error has occurred, that command is ignored.
Not Recognized
#12 Wrong I/O This error message occurs when an unsuitable device control command parameter is specified
Parameter (the initial value is set for the parameter which generated the error).
#13 Out of I/O This error message occurs with overflow of a device control command parameter.
Parameter Range
#14 Too Many This error message occurs when there are too many parameters or when not terminated using a
I/O Parameters colon.
#15 Error in I/O This error message occurs when a framing error, parity error, or overrun error occurs
Transmission duringdata transmission.
#16 I/O Buffer This error message occurs when the I/O buffer overflows. (Under such transmission.
Overflow circumstances, the plotter cannot perform plotting correctly.)
#17 Baudrate This error message occurs when there is an error with the setting for the rate of Turn off the
Error power and then turn it on again before transmitting data from the computer again.
#18 I/O Error An error other than those listed above has occurred.
Indeterminate
Error Message
Other Message
Message Notes
Motor Error Plug in the power supply again.
Power ON Again
Too Big Data
The amount of cutting data exceeds data buffer capacity.
Can not Replot
Pen Change : Pen No.
If the tool does not need to be changed, press the key without making any
Press Pause key changes. If you turn [TOOL STOP] to [OFF] in the control panel, this display will
no longer appear.
If an error message is displayed, the display can be cleared by pressing the key.
If the error message concerns an instruction, the message itself will be cleared by pressing the key, but the error
itself will not be cleared. In addition, if the error message is ignored in the unit is operated, operations past that point will
not be corrected. Sending an OE instruction from the computer or turning off the power to the unit will clear everything.