3 Replacement of Main Parts
43
3
7
Attach the Spring and tighten up the screws.
Then, connect the Y Motor Cable.
Spring
6
Drive
Belt
Put through the Y Motor Pulley to the Drive Belt and tighten
the Flange with the Motor temporarily.
Turn on the Power while pressing the [ ], [ ], [ ]
keys too enter the Service Mode.
Select the [LOAD] menu by pressing the [MENU] key and
press [ENTER] key.
<Y Axis Load Check>
8
CHECK MODE
LOAD CON. CARD
[ ], [ ], [ ] + POWER ON
[ENTER] key
[MENU] key
9
Select the [AXIS Y] in the [LOAD] menu and press [ENTER]
key. Then, Carriage moves to the Limit Position.
Enter the value 500 and press the [ENTER] key.
AXIS X Y Z S
[ENTER] key
AXIS X Y Z S
VALUE 500
[ENTER] key
AXIS X Y Z S
VALUE 500 OK