80
4 Adjustment
4
230mm
4-7 CALIBRATION (Referential Time : 20 minutes)
4
3
2
1
POWER ON
Check Mode
Check Mode
XY-COMP. Z-COMP.
X-COMP. Y-COMP.
<8333> <8333>
Enter the SERVICE MODE by turning on the power while
pressing [ ], [ ] and [ ] keys and select [XY-COMP.]
under the [Check Mode XY-COMP. Z-COMP.] and press
[ENTER] key.
Set both [X COMP.] and [Y COMP.] to default [8333] and
press the [ENTER] to save the settings.
Turn off the power after setting is completed.
Attach the ZEC-A2025 and ACRYLIC PLATE (over 25cm x
19cm) to the machine.
Turn on the power and set the other settings as shown
below.
Turn off the power after setting is completed.
SETTING :
HOME POSITION : Left Lower Corner
ZO : Surface of the material
Spindle RPM : 8,000 rpm
Turn on the power while pressing [ ] key to enter the
[Calibration Mode].
EGX-600/400 engraves as the figure.
190mm
5000rpm
15000rpm
8000rpm